Plate glass manufacturing

Glass manufacturing quality through moisture control

Measure dew point in blanketing atmosphere with Vaisala DRYCAP® sensor technology

During the plate glass manufacturing process, molten glass is very sensitive to moisture and is typically run under blanketing atmospheres where moisture is carefully monitored. The higher the quality of the glass, the more essential accurate moisture control becomes.

Dew point measurements are often made in harsh conditions with high temperatures and volatile chemical vapors. Due to the unique design of Vaisala’s DRYCAP® sensor, it is immune to most chemical contaminants found to offgas from this process.

Vaisala DRYCAP sensor layers named

DRYCAP technology tackles contaminants

DRYCAP is based on two innovations: the proven capacitive thin-film polymer sensor and the auto-calibration function. The sensor is heated at regular intervals during the automated auto-calibration procedure. The humidity and temperature readings are monitored as the sensor cools to ambient temperature, with offset correction compensating for any potential drift. This enables the DRYCAP sensor to deliver accurate measurements in demanding processes such as glass manufacturing, dramatically reducing the need for sensor maintenance.

Instruments for measuring dew point in glass manufacturing

Probe head and probe body of the DMP6 for very high temperatures

Dew Point Probe DMP6

Vaisala DRYCAP® Dew Point and Temperature Probe DMP6 is designed for in-line humidity measurement in industrial drying applications with very high temperatures and a wide dew point range.
Vaisala Insight Software gives quick access to the configurations and data of the Indigo family measurement probes and other supported devices.

Insight PC Software

Vaisala Insight PC Software gives quick access to the configurations and data of the Indigo family measurement probes and other supported Vaisala devices.
プローブ付きIndigo520

Indigo500 Series Transmitters

The Vaisala Indigo500 series transmitters are host devices for Vaisala Indigo-compatible, stand-alone smart probes. The Indigo500 series include multi-functional Indigo520 transmitter and Indigo510 transmitter with basic features.

Glass manufacturing measurement resources

ブログ

Indigo変換器を使用しますか?それともセンサプローブだけで十分ですか?

湿度、温度、露点、二酸化炭素、オイル内水分、過酸化水素蒸気などのさまざまな計測パラメータを選択できるように、多くのセンサプローブが用意されています。プローブは、Indigo500またはIndigo200シリーズの変換器に接続できます。どのような場合にセンサプローブだけで十分で、どのような場合にスマートプローブと変換器の両方が必要なのでしょうか。
E-mail Facebook Twitter LinkedIn