Transmission & Substation Design & Operation Symposium

LIFT-TSDOS
Loews Arlington Hotel & Convention Center, Arlington, TX
United States
Power Generation and Transmission
-

We’re excited to participate in this year’s Transmission & Substation Design & Operation Symposium (TSDOS), a premier forum where utilities, engineers, suppliers, contractors, and consultants come together to explore the latest trends, challenges, and solutions in transmission and substation design and operation. 

Attendees will gain valuable insight from industry experts through real-world case studies and open discussions that translate theory into practical, actionable knowledge. Be sure to visit Vaisala in our outdoor cabana space to learn how our Dissolved Gas Analysis solutions can enhance the reliability, safety, and planning of your grid assets, and stop by our partner Butler and Land’s tabletop just outside the Crystal breakout rooms to see how our combined offerings can support your next transmission or substation project.

How one electric co-op reduced operations and maintenance costs with versatile DGA monitoring

KAMO Power primarily uses manual sampling and outside labs for dissolved gas and moisture monitoring for its transformer fleet. This process is performed at least once a year, depending on the criticality of the transformer and its DGA history. The breadth of the KAMO territory, however, often requires taking two technicians off regular work to pull samples, not to mention allocating resources for the testing, including aggregating the DGA data results and the interpretation processes.

KAMO wanted to reduce this cost while improving confidence in the interpretation of the DGA monitoring data. This need for actionable insights was especially pronounced when an 84 MVA Waukesha began showing a concerning gassing trend in July of 2022 as the acetylene content increased from 0 ppm to 1.2 ppm. Up until this point, there had been no acetylene detected in annual DGA lab tests since the transformer had been placed in service. As an immediate response, per the lab recommendations, KAMO maintenance team increased the manual lab sampling frequency to every two weeks. After only a month, with two more samples pulled and tested, the DGA results indicated the acetylene had increased to 3.7 ppm.

In these situations where a potential transformer fault needed to be more closely monitored and the data more carefully analyzed because repair/outage decisions had to be made, KAMO realized that it could use a combination of multi-gas online DGA monitors and single gas and moisture monitors to replace more costly manual sampling.


To access the full customer story and learn how KAMO integrated these DGA solutions into its standard lab sampling operations, and how it improved operational effectiveness and proved out the concept for further implementation and roll out, please fill the form to the right. 

See our Privacy Policy for more details.
You can modify your preference settings or unsubscribe at any time here
DGA Calculator on smartphone with text and graphs

Turn your DGA data into Duval Triangles and Pentagon

Visualize the state of your power transformer, with Duval Triangles, Pentagon, and gassing trend graphs. Supports IEC & IEEE standards, as well as data import & export.