Transmitter |
| Type:
Operating frequency range:
Peak Power: Modulator:
| Coaxial Magnetron
5.5 - 5.7 GHz
250 kW Solid State |
Antenna |
| Type: Diameter: Gain (typical): Beam width: Peak Side Lobe (typical): Peak on Horizontal Axis (typical): Integrated Cross-Pol:
| Center-fed
parabolic reflector 4.5 m 45 dB <1 degree -28 dB -33 dB <-35 dB |
Pedestal |
| Type: Elevation Range: Maximum Scan Rate: Antenna/Pedestal: Operating: Storage: | Semi yoke elevation
over azimuth -3 to 110 degrees 40 deg/sec -40o to +55o C, 0 to 95% R.H., non
condensing -50o to +60o C |
RF-to-IF Receiver |
| Type: Dynamic Range: IF Frequency: | Dual stage, dual channel if downconverter
> 95 dB
442 / 60 MHz |
Digital IF Receiver and Signal Processor |
| Type: Dynamic Range (2.0 microsec): IF Digitizing: | Sigmet RVP8 > 95 dB (option 110 dB) 14 bits, 72 MHz in 3 channels |
Radar Controller |
| Type: | Sigmet RCP8 with Iris/Radar |
System Specifications | | Physical dimensions
Cabinet (w x h x d):
|
600 x 1800 x 1150 mm
|
|
Standard features | | HydroClassTM for real-time target
identification (hail, graupel, rain, snow, wet snow, non-met) Accurate attenuation correction Rainfall estimation based on KDP
|
|
|