Wind |
| Speed
Range
Response time
Available variables
Accuracy (range 0 ... 35 m/s) (range 35 ... 60 m/s)
Output resolution Direction
Azimuth
Response time
Available variables
Accuracy
Output resolution Measurement frame Averaging time
Update interval |
0 ... 60 m/s
250 ms
average, minimum, maximum
± 0.3 m/s or 3%, whichever is greater
±5 %
0.1 m/s, 0.1 km/h, 0.1 mph, 0.1 knots
0 ... 360°
250 ms
average, minimum, maximum
±3°
1°
1 ... 3600 s (=60 min), at one-second steps on the basis of samples taken at
4 Hz rate (configurable)
1 ... 3600 s (=60 min), at one-second steps
|
General |
| Serial data interface
Baud rate
Operating temperature
Storage temperature
Dimensions height diameter weight
Housing
Housing with mounting kit
Electromagnetic compatibility
IEC standards | SD-12, RS232, RS485,
RS422, USB adapter
1200 ... 115 200
-52 ... +60 °C (-60 ... +140 °F)
-60 ... +70 °C (-76 ... +158 °F)
139 mm (5.47")
114 mm (4.49")
510 g (1.12 lb)
IP65
IP66
complies with EMC standard EN61326-1, Industrial Environment
IEC 60945 paragraph 8, vibration
IEC 60945/61000-4-2 … 61000-4-6 |
Power supply |
| Input voltage
Typical power consumption on average
Heating voltage | 5 ... 32 VDC
3 mA at 12 VDC (default measuring intervals)
5 … 32 VDC (or Ac, max. 30 VRMS) |
For complete specifications, please see the
datasheet or user guide in "Product Documentation".