Vaisala Surge Protector WSP150

  • Superior, three-stage transient surge protection
  • Tolerates up to 10 kA surge currents
  • Noise filtering against HF and RF interference
  • Robust structure
  • IP66 housing
  • Both differential and common mode protection on each channel
  • 2 power and 2 data channels
  • Can be used with all Vaisala wind and weather instruments
  • Applications: mast installations of weather measurement networks, MET stations in wind parks

 

Maximum characteristics

Input voltage
(across channel line pair and from line to GND,
terminals #3)
     power channels
     data channels

Input common mode voltage
     any line to earth

Throughput current
     power lines
     data lines

Throughput resistance
(per line)
     power lines
     data lines

Turn-on voltage
     power channels
     data channels

Surge current
     to earth
     differential

EMC surge tolerance





max. ± 43 V
max. ± 13 V


max. ± 72 V


max. 1.5 A
max. 0.16 A



0.3 ohms
15 ohms


max. ± 60 V
max. ± 16 V


max. 10 kA
m
ax. 5 kA

EN 61000-4.5, (4 kV, 2 kA)
IEEE C62.45 (6 kV, 3kA)

General

Operating and storage temperature

Installation and maintenance work temperature

Environmental protection class

Dimensions
     housing (w x h x d)
     with cable glands and
     mounting assembly

     cable
     wires

Housing material

Weight


-52 ... +70 °C (-60 ... +158 °F)


-40 ... +70 °C (-40 ... +158 °F)


IP66 (NEMA 4X)


130 x 94 x 58 mm

130 x 120 x 69 m
m

Ø 4 ...
8 mm
Ø 4 ... 1.7 mm (AWG 26 - 14)

polycarbonate, stainless steel

0.65 kg