Visibility (MOR) measurement |
| PWD10 and PWD12: Measurement range
PWD20, PWD20W and PWD22: Measurement range |
10 ... 2000 m (32 ft ... 1.2 miles)
10 ... 20 000 m (32 ft ... 12 miles)
|
Present weather |
| PWD12: Identifies
Reports
PWD22: Identifies
Reports |
4 different types of precipitation (rain, drizzle, mixed rain/snow, snow)
Fog, mist, haze (smoke, sand) or clear
WMO 4680 (SYNOP) and NWS code tables
39 different codes supported from WMO 4680 code table
7 different types of precipitation (rain, freezing rain, drizzle, freezing
drizzle, mixed rain/snow, snow, ice pellets)
Fog, mist, haze (smoke, sand) or clear.
WMO 4680 (SYNOP), 4678 (METAR) and NWS code tables
49 different codes supported from WMO 4680 code table
|
Operating environment |
| Temperature
Humidity | -40...+60 °C
0...100 %RH |
Inputs and outputs |
| Outputs
Operating voltage
Power consumption PWD10, PWD20 and PWD20W PWD12 and PWD22 | RS232, RS485, analog
current, relay control
12 VDC ... 50 VDC (electronics)
24 VAC or 24 VDC for heater option
3 W (electronics with dew heater @ 12VDC)
6 W |
Mechanics |
| Dimensions
Weight | 40.4 (w) x 69.5 (l)
x 19.9. (h) cm
(15.91" (w) x 27.36" (l) x 7.83" (h))
3 kg (7 lb) |
For complete specifications, please see the brochure
or user guide in "Product Documentation".