Visibility (MOR) measurement |
| Measurement range
(MOR)
Accuracy | 5 ... 75 000 m with
1, 3 and 10-minute averaging
+10 % range 5 ... 10 000 m
+20 % range 10 000 ... 75 000 m |
Optical |
| Scattering angle
Optical monitoring
| 42°
Window contamination measurement and compensation circuitry
Optical path blockage detection
Light source stability control |
Operating environment |
| Temperature
Humidity
Wind | -40...+65 °C
0...100 %RH
60 m/s |
Inputs and outputs |
| Operating voltage
Power consumption
Outputs
| 100/115/230 VAC
+/-10 %, 50-60 Hz
300 W maximum (60 VA + 240 VA defrosting heaters)
Serial line RS-232 or opto-isolated RS-485 (2-wire) or optinal data modem
Separate RS-232 maintenance line |
Mechanics |
| Dimensions
Weight | 2.8 (h) x 0.9 (w) x
0.5 (d) m
37 kg, including interface unit, mast and base plate |
For complete specifications, please see the brochure
or user guide in "Product Documentation".