Relative humidity measurement |
| Measurement range
Accuracy at +20 °C (68 °F)
Sensor | 0 ... 100 % RH
± 1.0 % RH (0 ... 90 % RH)
± 1.7 % RH (90 ... 100 % RH)
Vaisala HUMICAP® 180 |
Temperature measurement |
| Measurement range
Accuracy at +20 °C (68 °F)
Sensor | -70 ... +180 °C
± 0.2 °C
PT100 RTD 1/3 Class B IEC 751 |
Other variables available (depends
on model) |
| Dewpoint,
temperature, mixing ratio, absolute humidity, wet bulb temperature, enthalpy,
water vapor pressure. |
Operating environment |
| Temperature for probe for transmitter body with display
Pressure |
same as measurement ranges
-40 ...+ 60 °C (-40 ... +140 °F)
0 ...+ 60 °C (+32 ... +140 °F)
vapor tight
|
Inputs and outputs |
| Operating voltage with optional power supply module
Power consumption @ 20 °C (Uin
24 VDC) RS-232 Uout 2 x 0 ... 1 V/ 0 ... 5 V/ 0... 10 V Iout 2 x 0 ... 20 mA V
Analog outputs current output voltage output
Digital outputs
Menu languages | 10 ... 35 VDC, 24
VAC
100 ... 240 VAC 50/60 Hz
max. 25 mA
max. 25 mA
max. 60 mA
0 ... 20 mA, 4 ... 20 mA
0 ... 1 V, 0 ... 5 V, 0 ... 10 V
RS-232, RS-485 (optional)
English, French, Spanish, German, Japanese, Russian, Swedish, Finnish |
Mechanics |
| Probe cable diameter
Material (housing)
Housing classification | 5.5 mm
G-AlSi 10 Mg (DIN 1725)
IP65 (NEMA 4) |
For complete specifications, please see the brochure
or user guide in "Product Documentation".