Vaisala Wind Set WA15

 

 Contact Us

 


 

Learn More

CEN_rightcolumncode2
    Overview
     

     Overview

     
    • High-performance wind measurement set
    • Long and successful track record in meteorological applications
    • Low measurement starting threshold
    • Conical anemometer cups provide excellent linearity
    • Heated shaft prevents bearings from freezing
    Technical Specifications
     

     Technical Specifications

     

    Wind speed

     

    Sensor / transducer type
    Measurement range
    Starting threshold
    Distance constant
    Accuracy (range 0.4...60 m/s)
        with characteristic transfer function
        with transfer function U=0.1xR

    cup anemometer / opto-chopper
    0.4...75 m/s
    <0.5 m/s *
    2.0 m

    ±0.17 m/s **
    ±0.5 m/s

    * Measured with cup wheel in position least favoured by flow direction. Optimum position gives approx. 0.35 m/s threshold.
    ** Standard deviation.

    Wind direction


    ​Sensor / transducer type
    vane / optical code disc

    ​Measurement range
    (wind speed 0.4...75 m/s)
    ​0...360°

    ​Starting threshold ​<0.4 m/s

    ​Delay distance ​0.4 m

    ​Resolution ​±2.8°

    ​Accuracy ​better than ±3°

    Inputs and outputs


    ​Operating power supply
          WAA151, WAV151


    U=9.5...15.5 VDC, 20 mA typical

    ​Heating power supply
          WAA151, WAV151

    20 VAC or VDC, 500 mA nominal

    ​Output for WAA151 (wind speed)


    ​      Transducer output ​0...75 m/s = 0...750 Hz square wave

    ​      Transfer function U = 0.328 + 0.101 x R
    (U = wind speed [m/s], R = o/p pulse rate [Hz])


    ​      Transducer output
          level
    ​​(Iout < +5 mA) high state > Uin-1.5 V
    (Iout > -5 mA) low state < 2.0 V

    ​Output for WAV151 (wind direction)

    ​     Transducer output ​6-bit parallel GRAY code

    ​     Transducer output
         level
    ​(Iout < +5 mA) high state > Uin-1.5 V
    (Iout > -5 mA) low state < 1.5 V          

    Operating temperature

     

    With shaft heating
    Storage temperature

    -50...+55 °C (-58...+131 °F)
    -60...+70 °C (-76...+158 °F)

    For complete specifications, please see the datasheet or user guide in "Documents".

    Services
     

     Services

     

    Technical Support
    Get fast, easy access to professional support over the entire life cycle of your equipment. The Vaisala HelpDesk is your single contact point for technical inquiries related to Vaisala products and systems.   

    Spare Parts
    Get rapid access to the spare parts you need to maximize the uptime of your equipment and ensure reliable and accurate operation. In addition to standard spare part delivery, we also offer an express service where parts are shipped within one business day.

    Repair Services
    Vaisala repair services include fault tracing and repair or replacement of failed components, as well as final testing to ensure your equipment is functioning properly. Repairs can be carried out on site or at one of our service centers.

    Warranty
    All Vaisala products and services are covered by a 12-month warranty as standard, with selected products covered for up to 24 months. During this period you benefit from free repair or replacement of faulty equipment. With Vaisala’s extended warranty, you get free repair or replacement for five years.