Water dewpoint measurement |
|
Measurement range Accuracy Sensor |
-50 ... +50 °C (-58 ... +122 °F) Td ± 2 °C (± 3.6 °F) Vaisala HUMICAP® 180M |
Temperature measurement |
|
Measurement range Accuracy of electronics at +20 °C (+68 °F) Sensor |
-40 ... +100 °C (-40 ... +212 °F)
± 0.2 °C (± 0.36 °F) Pt 1000 RTD 1/3 Class B IEC 751
|
Operating environment |
|
Temperature operation storage Pressure HMT362 HMT364 HMT368 |
-20 ... +60 °C (-4 ... +140 °F) -40 ... +70 °C (-40 ... +158 °F)
0 ... 16.7 MPa 0 ... 10 MPa 0 ... 4 MPa
|
Inputs and outputs |
|
Operating voltage with serial port (service mode) Analog outputs Display |
12 ... 28 VDC
15 ... 28 VDC two-wire 4 ... 40 mA, one standard, one optional two-line LCD
|
Mechanics |
|
Cable bushing Weight (housing) Material (housing) Housing classification |
Pg11 (5 ... 12 mm) 950 g G-AlSi10Mg (DIN 1725) IP66 (NEMA 4X)
|
Options and accessories |
|
Additional analog output Ball valve set (for HMP368) Serial interface cable for PC Sampling cell for HMP362 Galvanic isolator (EU) Zener barrier (USA&Canada)
|
4 ... 20 mA BALLVALVE-1 25905ZZ HMP302SC 212483 210664 |
For complete specifications, please see the brochure or manual in "Documents".