Overview
|
The Vaisala HUMICAP® Humidity and Temperature Transmitter Series HMT330 is designed for demanding applications where stable measurement and wide customization is important.
- Six models for demanding applications:
- HMT331 for wall mounting
- HMT333 for duct mounting and tight spaces
- HMT334 for high pressures up to 100 bar and vacuum conditions
- HMT335 for high temperatures
- HMT337 for high humidity and meteorological applications
- HMT338 for pressurized pipelines up to 40 bar
- Warmed probe for superior performance in condensing environments
- Shows measurement trends and history graphically
- Corrosion resistant IP65 housing
- NIST traceable (certificate included)
- Optional integrated data logging, with over four years of measured history
- LAN and WLAN communication options
- Compatible with the Vaisala Continuous Monitoring System
|
Technical Specifications
|
Relative humidity measurement |
|
Measurement range Accuracy at +20 °C (68 °F)
Factory calibration uncertainty
Sensor
|
0 ... 100 % RH ± 1.0 % RH (0 ... 90 % RH) ± 1.7 % RH (90 ... 100 % RH) (+20 °C) ± 0.6 % RH (0 ... 40 %RH) ± 1.0 % RH (40 ... 97 %RH) (Defined as ±2 standard deviation limits. Small variations possible, see also calibration certificate.) Vaisala HUMICAP® 180(C) Vaisala HUMICAP® 180R(C)
|
Temperature measurement |
|
Measurement range HMT331 HMT333
HMT334/335/337/338 Accuracy at +20 °C (68 °F) Sensor |
-40 ... +60 °C (-40 ... +140 °F) -40 ... +80 °C or -40 ... +120 °C (-40 ... +176 °F or -40 ... +248 °F) -70 ... +180 °C (-94 ... +356 °F) ± 0.2 °C Pt100 RTD 1/3 Class B IEC 751
|
Other variables available (depends on model) |
|
Dewpoint, temperature, mixing ratio, absolute humidity, wet bulb temperature, enthalpy, water vapor pressure.
|
Operating environment |
|
Temperature for probe for transmitter body with display Pressure HMT334 HMT338 HMT333/335/337 |
same as measurement ranges -40 ...+ 60 °C (-40 ... +140 °F) 0 ...+ 60 °C (+32 ... +140 °F)
0 ... 10 MPa (0 ... 100 bar) 0 ... 4 MPa (0 ... 40 bar) vapor tight
|
Inputs and outputs |
|
Operating voltage with optional power supply module Power consumption @ 20 °C (Uin24 VDC) RS-232 Uout2 x 0 ... 1 V/ 0 ... 5 V/ 0... 10 V Iout2 x 0 ... 20 mA V Analog outputs current output voltage output Digital outputs
Ethernet interface (optional) Supported standards Connector Protocols WLAN interface (optional) Supported standards Antenna connector type Protocols Security Authentication / Encryption Open / no encryption Open / WEP WPA Pre shared key / TKIP WPA Pre shared key / CCMP (a.k.a. WPA2)
Optional data logger with real-time clock Logged parameters Logging interval Max. logging period Logged points Battery lifetime Menu languages |
10 ... 35 VDC, 24 VAC
100 ... 240 VAC 50/60 Hz
max. 25 mA
max. 25 mA max. 60 mA
0 ... 20 mA, 4 ... 20 mA 0 ... 1 V, 0 ... 5 V, 0 ... 10 V RS-232, RS-485 (optional)
10/100Base-T RJ45 Telnet
802.11b RP-SMA Telnet WEP 64/128,WPA
max. three with trend/min/max values 10 sec (fixed) 4 years 5 months 13,7 million points per parameter min. 5 years English, French, Spanish, German, Japanese, Russian, Swedish, Finnish, Chinese
|
Mechanics |
|
Probe cable diameter HMT333 other probes Material (housing) Housing classification |
6.0 mm 5.5 mm G-AlSi 10 Mg (DIN 1725) IP65 (NEMA 4)
|
For complete specifications, please see the brochure or user guide in "Documents".
|
Related Services
- Service Center Calibration
Regular calibration ensures that your Vaisala equipment continues to provide accurate, high-quality data. We offer traceable, standards-compliant calibration services for almost all Vaisala products and partner with world-class couriers for rapid, trouble-free return of your equipment.- On-Site Calibration
On-site calibration helps you maximize both reliability and profitability by minimizing costly equipment downtime and ensuring compliance with relevant regulations and standards. Our expert engineers can also replace a range of components, carry out minor repairs, and provide the latest upgrades.- Repair Services
Vaisala repair services include fault tracing and repair or replacement of failed components, as well as final testing to ensure your equipment is functioning properly. Repairs can be carried out on site or at one of our service centers.- Spare Parts
Get rapid access to the spare parts you need to maximize the uptime of your equipment and ensure reliable and accurate operation. In addition to standard spare part delivery, we also offer an express service where parts are shipped within one business day.- Warranty
All Vaisala products and services are covered by a 12-month warranty as standard, with selected products covered for up to 24 months. During this period you benefit from free repair or replacement of faulty equipment. With Vaisala’s extended warranty, you get free repair or replacement for five years.
Documents
- Die Wahl des richtigen Sensors zur Außenfeuchte-messung ist entscheidend für die Wirtschaftlichkeit eines Systems mit freier Kühlung (pdf, 339KB)
- Le choix des capteurs d’humidité extérieurs est crucial pour obtenir un système économique de refroidissement gratuit (pdf, 343KB)
- Choice of outdoor humidity sensors critical to economical free cooling system (pdf, 173KB)
- Humidity Measurement in Cleanrooms (pdf, 239KB)
- Optimizing gas turbine performance with precise humidity measurements (pdf, 367KB)
- Humidity and Temperature Transmitters in Automotive Paint Booth Applications (pdf, 40KB)
- Calibration and Adjustment of Humidity Instruments - Pros and Cons of Different Methods (pdf, 239KB)
- Kalibrierung und Justierung von- Vor- und Nachteile verschiedener Methoden (pdf, 272KB)
- How to Choose the Right Instrument for Measuring Humidity and Dew Point (pdf, 565KB)
- Comment choisir le bon instrument pour la mesure de l’humidité et du point de rosée (pdf, 615KB)
- Humidity Measurement in Hydrogen Peroxide Sterilization Process in Life Science Industry (pdf, 370KB)
- Die Wahl des richtigen Produkts für Feuchte- und Taupunktmessungen (pdf, 748KB)
- Outdoor Wet Bulb Temperature - The Defining Measurement for Cooling Tower Operations (pdf, 262KB)
- Measuring Humidity and Dew Point in Environments with Chemical Contaminants (pdf, 577KB)
- Measuring Humidity in High Humidity Environments (pdf, 284KB)
- 室外湿球温度- 确定冷却塔运行的测量值 (pdf, 316KB)
- 室外湿球温度- 确定冷却塔运行的测量值 (pdf, 317KB)
- 洁净室的湿度测量 (pdf, 528KB)
- Feuchtemessung in Reinräumen (pdf, 393KB)
- Mesure de l’humidité dans les salles blanches (pdf, 248KB)
- Mesure de l’humidité et du point de rosée dans des environnements ayant des contaminants chimiques (pdf, 542KB)
- Die Feuchttemperatur der Außenluft – der entscheidende Messwert für den Kühlturmbetrieb (pdf, 305KB)
- 如何正确选择湿度与露点测量仪表 (pdf, 801KB)
- Calibração e Ajustes de instrumentos de Umidade – Prós e Contras dos diferentes métodos (pdf, 276KB)
- Cómo elegir el instrumento correcto para medir humedad y punto de rocío (pdf, 780KB)
- Feuchte- und Taupunktmessungen in chemisch belasteten Umgebungen (pdf, 558KB)
- Improve Your Wood Drying Process with Accurate Humidity Measurements (pdf, 243KB)
- Paranna puunkuivausprosessia tarkoilla kosteusmittauksilla (pdf, 245KB)
- 高湿度环境下的湿度测量 (pdf, 312KB)
- HMT330 Broschüre auf deutsch (pdf, 4506KB)
- DNV Type Approved Product Certificate No.: A-11440 (pdf, 1421KB)
- HMT330製品カタログ (pdf, 1016KB)
- HMT330 Series Datasheet in English (pdf, 1311KB)
- HMT330系列温湿度变送器产品介绍 (pdf, 1438KB)
- HMT330 combinado Panfleto em português (pdf, 1360KB)
- HMT330 combiné Brochure en français (pdf, 1363KB)
- HMT338中文选型表201303.pdf (pdf, 493KB)
- HMT330 Calibration Order Form (pdf, 28KB)
- HMT330 Order Form Global (pdf, 140KB)
- HMT331オーダーフォーム (pdf, 168KB)
- HMT333オーダーフォーム (pdf, 187KB)
- HMT334オーダーフォーム (pdf, 188KB)
- HMT335オーダーフォーム (pdf, 187KB)
- HMT337オーダーフォーム (pdf, 193KB)
- HMT337FCオーダーフォーム (pdf, 204KB)
- HMT337Wオーダーフォーム (pdf, 156KB)
- HMT338オーダーフォーム (pdf, 188KB)
- HMT331 产品选型表 (pdf, 431KB)
- HMT333 产品选型表 (pdf, 492KB)
- HMT334 产品选型表 (pdf, 426KB)
- HMT335 产品选型表 (pdf, 426KB)
- HMT337 产品选型表 (pdf, 429KB)
- HMT337W 产品选型表 (pdf, 429KB)
- HMT338 产品选型表 (pdf, 493KB)
- HMT338中文选型表 (pdf, 493KB)
- HMT338中文选型表 (pdf, 493KB)
- HMT330WPA Installation Instructions in English (pdf, 445KB)
- HMT330, DMT340, MMT330, PTU300 Multilingual Quick Guide (pdf, 1346KB)
- Vaisala HUMICAP Sensor for Measuring Relative Humidity (pdf, 274KB)
- Vaisala HUMICAP® -anturi suhteellisen kosteuden (RH) mittaamiseen (pdf, 303KB)
- Vaisala HUMICAP® sensor voor relatieve vochtigheidsmeting (pdf, 301KB)
- Capteur Vaisala HUMICAP® pour mesure de l’humidité relative (pdf, 287KB)
- ヴァイサラHUMICAP®相対湿度センサ (pdf, 4083KB)
- Vaisala HUMICAP®-sensorn för mätning av relativ luftfuktighet (pdf, 249KB)
- 维萨拉的HUMICAP® 传感器用于测量相对湿度 (pdf, 415KB)
- Vaisala HUMICAP® Sensor para Medição de Umidade Relativa (pdf, 300KB)
- Sensor Vaisala HUMICAP® para medir humedad relativa (pdf, 268KB)
- Vaisala HUMICAP® Sensor zur Messung der rel. Feuchte (pdf, 932KB)
- HMT330 Bedienungsanleitung auf Deutsch (pdf, 3222KB)
- HMT330 Bruksanvisning på svenska (pdf, 3219KB)
- HMT330 Manuel utilisateur en français (pdf, 3264KB)
- HMT330 Suomenkielinen käyttöohje (pdf, 3290KB)
- HMT330 用户手册 (pdf, 1464KB)
- HMT330 ИНСТРУКЦИЯ ПО ЭКСПЛУАТАЦИИ (pdf, 2657KB)
- HMT330 User Guide In English (pdf, 2388KB)
- HMT330取扱説明書 (pdf, 2317KB)
- Certified Reliability For The Seas (pdf, 639KB)
- Humidity Measurement in Cleanrooms - The Devil Is in the Details (pdf, 231KB)
- 21st Century 4-stroke Engine Based Power Plants Rely on Vaisala Humidity Measurement (pdf, 285KB)
- Optimal Timber Drying Conditions at the Korkeakoski Sawmill (pdf, 211KB)
- Strong in Extreme Conditions (pdf, 331KB)
- Cool Down the Environmental Way (pdf, 233KB)
- HMT330 DMT340 MMT330 Wiring Diagram in English (pdf, 358KB)
- POWER-1 Power Supply Module Installation Instructions in English (pdf, 441KB)
Applications
- Measurement and Monitoring in High-Technology Cleanrooms
- Measuring Dew Point in Compressed Air
- Monitoring Humidity to Optimize Gas Turbine Performance
Monitoring humidity to optimize gas turbine performance.- Monitoring Construction Material Manufacturing
- Monitoring the Fluid Bed Dryer Performance
- Controlling Humidity Level in Bakeries
- Measurement and Monitoring in Glove Boxes and Isolators
- Measuring Dew Point in Furnace Gas
- Metrology for Industrial Measurements
- Measuring Humidity of Air Exiting from the Paper Mill Hood
- Measurement and Monitoring in Semiconductor Tools
- Measurement and Monitoring in Test Chambers
- Ship Instrumentation for dynamic positioning and navigation and to maximize ship machinery performance
You can improve safety and efficiency by getting precise real-time information on prevailing wind conditions and machinery performance.- Clean Room Measurement and Monitoring in Life Science
Vaisala’s environmental monitoring solution for pharmaceutical and biotechnical clean rooms provides remote monitoring, audit-ready reports, and 24/7 alarming for temperature, humidity, differential pressure, flow and other critical and parameters.- Incubator Monitoring with Alarm, Incubator Validation / Mapping, Test Chamber Temperature & Humidity Monitoring, Chamber CO2 Monitoring
Medical, Pharmaceutical, Biotechnical incubator monitoring with alarming, Web-based environmental management and 21 CFR Part 11 reporting for life science environments and critical scientific incubator applications.- Monitoring and Mapping System for Stability Test Chambers and Stability Test Rooms
The Vaisala stability chamber monitoring system provides independent real-time trends and audit trail with flexible alarming and customizable reporting. Ideal for ICH and FDA-compliant stability studies and package testing.- Outdoor Measurements for Building Automation
- Monitoring Humidity to Optimize Gas Turbine Performance
Monitoring humidity to optimize gas turbine performance.- Matching Environmental Monitoring & Mapping to FDA/ICH Guidance for Better Stability Studies
- Compressed Air Measurement Knowledge Base
|
|