Performance |
|
Cloud reporting range Backscatter profiling range Reporting cycle |
0 ... 13 km (0 ...43,000 ft.) 0 ... 15 km (0 ...49,200 ft.) programmable 6...120 s, or polling |
Reported quantities |
|
Cloud hits (up to 3 layers) and status information Cloud hits, status and backscatter profile Emulation of CL31 and LD-40 Sky Condition (optional) |
Operating environment |
|
Temperature Relative humidity Wind |
-55...+60 °C (-67...+140 °F) 0 ...100 %RH 55 m/s |
Inputs and outputs |
|
Operating voltage Power consumption Outputs |
100/115/230 VAC max. 310 W including heating RS-232/RS-485/ Modem V.21, V.22, V22bis |
Mechanics |
|
Dimensions: Total Measurement unit Weight: Total Measurement unit Housing classification |
1531 x 364 x 354 mm 834 x 266 x 264 mm
46 kg 18,6 kg IP65
|
For complete specifications, please see the brochure in "Documents".