Vaisala Veriteq Wide Range Temperature VL 1016/1416 Loggers

​The Vaisala Veriteq Multi-application data logger can simultaneously monitor different temperature ranges in up to four chambers— -80°C ultra-low temperature freezers, freezer/refrigerator units and incubators.
It eliminates the need to purchase and install additional hardware — loggers and network access points — otherwise required for measuring different temperature ranges.

Vaisala goes to great lengths to ensure recorder accuracy with NIST-traceability and multipoint calibration, especially down to very low temperatures. We use highly specialized liquid baths rated for -100°C in our own A2LA accredited calibration laboratory. We are also the only company to state measurement accuracy for its products after one-year.

The 10-year internal battery and on-board memory in each Multi-application logger provide immunity from power outages and network downtime.

 

 Contact Us

 


 

Learn More

LSH_rightcolumn_price_chat_adv_tech
    Technical Specifications
     

     Technical Specifications

     

    General

    Size 3.4 x 2.1 x 1" (85 x 59 x 26mm);
    60g (2.7 oz)
    Operating Range -95°C to +70°C (-139°F to 158°F) through probes
    Interfaces RS-232 serial port; Ethernet; PoE & WiFi interfaces available
    Mounting Magnetic strips; 3M Dual Lock™Fasteners; Snap-in connector locks provide secure probe connections
    PC Software
    • viewLinc automated monitoring, alarming & reporting
    • OPC server software to add Vaisala Veriteq loggers to any OPC-compatible monitoring system
    Clock Accuracy: ±1 min./month at 0°C to +50°C (+32°F to +122°F)
    Electromagnetic Interference Meets FCC Part 15 for digital devices; meets CE requirements for radiated emissions, electrostatic discharge, and radiated susceptibility.
    Power Source Internal lithium battery with life of 10 years at 1 minute sampling rate.


    Multi-Application Temperature Recorder Accuracy

    Sensor Calibrated
    Measuring Range
    Resolution One year Accuracy
    V Range External Probe

    -90°C to +50°C

    (-130°F to +122°F)

    0.01°C at +25°C

    (0.02°F at +77°F)

    ±0.35°C over -90°C to +50°C

    (±0.63°F over -130°F to +122°F)

    Memory

    Memory Type Non-volatile EEROM
    Data Sample Capacity

    1016 - 68,600 16-bit samples (2 channels)

    1416 - 101,375 16-bit samples (4 channels)

    Memory Modes User-selectable: Wrap when memory full (FIFO) or Stop when memory full. User-selectable start time and (for VL series) stop time.
    Memory Protection Data retention > 20 years backup without power.
    Sampling Rates User-selectable rates from once every 10 seconds to once a day. Note: 10 year battery life is specified at a 1 minute sample rate.
    Recording Span Recording span depends on sample interval selected and number of channels enabled. Chart below details some typical sampling rates and length of time logger will retain data in memory before wrapping around or stopping (see Memory Modes).


    Recording Span: 1016 - 22V

    Sample Interval
    1 Channel
    2 Channels
    1 minute
    1.5 Months
    23.8 Days
    5 minutes
    7.6 Months
    3.8 Months
    15 minutes
    1.9 Years
    11.5 Months
    1 hour
    7.8 Years
    3.9 Years


    Recording Span: 1416 - 44V

    Sample Interval
    1 channel
    2 channels
    3 channels
    4 channels
    1 minute
    2.3 Months
    1.1 Months
    23.5 Days
    17.6 Days
    5 minutes
    11.3 Months
    5.6 Months
    3.7 Months
    2.8 Months
    15 minutes
    2.8 Years
    1.4 Years
    11.3 Months
    8.5 Months
    1 hour
    11.5 Years
    5.7 Years
    3.8 Years
    2.8 Years


    Temperature Probes: Stainless or Teflon Tip

    Sensor
    Operating Range
    Color Code
    Sensor Tip
    Probe Length
    Cable Construction
    V Range external probe:EPT-23N-XXV

    -95°C to +70°C

    (-139°F to +158°F)

     

    Blue

     
    Stainless Steel Diameter: 3.2 mm (1.8") length: 38mm (1.5")

    XX denotes length of probe in feet.

    3 m(10') and 7.6 m (25') probes available.

    2mm (0.07") Diameter Teflon coated cable
    V Range external probe:EPT-22W-XXV
    Sealed Teflon Tip Diameter: 3mm (0.12") Length: 28mm (1.1")


    Temperature Probe Accessories

    Thermal Dampening Block for use in refrigerators and freezers. Simulates a glycol bottle to reduce viewLinc alarms generated by opening and closing a door.

    Related Services
    • Service Center Calibration 
    • Regular calibration ensures that your Vaisala equipment continues to provide accurate, high-quality data. We offer traceable, standards-compliant calibration services for almost all Vaisala products and partner with world-class couriers for rapid, trouble-free return of your equipment.
    • On-Site Calibration 
    • On-site calibration helps you maximize both reliability and profitability by minimizing costly equipment downtime and ensuring compliance with relevant regulations and standards. Our expert engineers can also replace a range of components, carry out minor repairs, and provide the latest upgrades.
    • Repair Services 
    • Vaisala repair services include fault tracing and repair or replacement of failed components, as well as final testing to ensure your equipment is functioning properly. Repairs can be carried out on site or at one of our service centers.
    • Spare Parts 
    • Get rapid access to the spare parts you need to maximize the uptime of your equipment and ensure reliable and accurate operation. In addition to standard spare part delivery, we also offer an express service where parts are shipped within one business day.
    • Warranty 
    • All Vaisala products and services are covered by a 12-month warranty as standard, with selected products covered for up to 24 months. During this period you benefit from free repair or replacement of faulty equipment. With Vaisala’s extended warranty, you get free repair or replacement for five years.