Skip Ribbon Commands
Skip to main content

DL1700 Thermocouple Data Logger

Thermocouple Data Loggers, NIST Traceable
​ The Vaisala DL1700 series data loggers provide highly accurate temperature data acquisition and are ideal for demanding environments. The data loggers are used with Vaisala's software: either vLog for downloading and analysis, or viewLinc for monitoring and alarming.

  • Ideal for extreme temperatures – from -240 °C to 1760 °C
  • Accepts type J, K, T, E, R and S thermocouples
  • No programming or complicated equations required
  • Highly accurate replacement for bulky data acquisition systems



    Contacts & Pricing

     Contacts & Pricing

     

     Features

    • ​Battery-powered data loggers connect with commonly available thermocouple temperature probes
    • Single or multi-input models record temperatures between -240° C to 1760° C
    • User-configurable data logger inputs accept type J, K, T, E, R and S thermocouples
    • High impedance inputs maximize accuracy and allow use with long or thin gauge thermocouple probes
    • Includes automatic cold junction temperature compensation
    • Includes internal memory and ten-year battery
    • Choose DL1700 VL models for validated GxP environments and DL1700 SP models for non-validated environments
    Technical Specifications

     Technical Specifications

    General

    Size

    3.4 x 2.1 x 1" (85x59x26mm); 60g (2.7 oz)

    Operating Range

    -40 to 85° C. (-40 to 185° F.) and
    0 to 95% RH

    Interfaces

    RS-232 serial port; Ethernet, WiFi

    Mounting

    3M Dual Lock TM fasteners

    PC Software

    viewLinc for continuous monitoring & alarming
    vLog for graphing & reporting

    Clock

    Accuracy: ± 1 min./month at -25 to 70° C.

    Electromagnetic Interference

    Meets FCC Part 15 for digital devices; meets CE requirements for radiated emissions, electrostatic discharge, & radiated susceptibility.

    Power Source

    Internal lithium battery with life of 10 years at 1 minute sampling rate.

    Datalogger Inputs

     

    Model

    No. of Channels Enabled

                        Total

    CJT

    Thermocouple

    1700-54T

    5

      1

    4

    Note: One channel is designated for Cold Junction Temperature (CJT) reference using an on-board precision-tolerance thermistor.

    Thermocouple Input Channels

    Compatible thermocouple types J, K, T, E, R, S


     

    Input Impedance:

    10M ohms

    Input Range:

    Resolution:

    Accuracy:

    -7.2 to 55.4 mV

    0.016 mV

    ± 0.055 mV @ 25°C


    Thermocouple Ranges & Accuracy

    Temperature Accuracy

    Thermocouple

    K

     J

     T

     E

     R

     S

    Temperature Measurement Range

    -220 to 1370°C

    -130 to 900°C

    -240 to 350°C

    -110 to 740°C

    -50 to 1760°C

    -50 to 1700°C

    Instrument Temperature Accuracy
    at mid range

    ±1.3°C

    ±1.0°C

    ±1.2°C

    ±0.70°C

    ±4.4°C

    ±5.1°C

    Resolution 
    at mid range

    0.37°C

    0.29°C

    0.34°C

    0.20°C

    1.3°C

    1.5°C


    Cold Junction Temperature Channel

    Measurement range

    -40°C to +85°C
    (-40°F to +185°F)

    Accuracy

    ±0.25°C over +20°C to +30°C
    (±0.45°F over +68°F to +86°F)
    ±0.35°C over -20°C to +70°C
    (±0.63°F over -4°F to +158°F)

    Memory

    Data Sample Capacity

    135,165 12-bit samples

    Memory Modes

    User-selectable start time. User selectable: Wrap when memory full, or Stop when memory full.

    Memory Protection

    Data retention > 20 years backup without power.

    Sampling Rates

    User-selectable (in intervals of 10 seconds) from once every 10 seconds to once a day.

    Recording Span

    Recording span depends on sample interval selected and number of channels enabled. Below chart details typical sampling rates and length of time logger will retain data in memory before wrapping around or stopping (see Memory Modes).

    Accessories

    ​Thermocouple probe

    ​EPT-22T-20T

    ​Type

    ​T

    ​Conductors

    ​Copper/Constantan

    ​Operating Range

    ​-200°C to 200°C (-328°F to 392°F)

    ​Length

    ​6.096 m

    Error

    +/-1°C to ± 1.5%


     


     