Connectivity Devices

vNet Power over Ethernet (PoE) Logger Interface 

The vNet Power over Ethernet (PoE) Logger Interface is a snap-in cradle that allows Vaisala data loggers to be powered by data cable from your Ethernet network, often at a lower cost than with alternative power sources normally required between loggers and networking devices.

When used with a vNet device, Vaisala data loggers can be powered by PoE or local supply voltage (AC).  The advantage of the vNet PoE is the simplicity of single-cable connectivity. vNet AC is available for networks that do not support PoE.

Both PoE and AC models of vNet use viewLinc Aware firmware to find vNet devices and automatically configure them for network settings.  vNet Aware also allows data loggers to exist dynamically on the network so that they can be easily moved and quickly reconfigured.

For further information,  request pricing.

vNet PoE data logger connectivity cradle

 Contact Us



 

Learn More

    Technical Specifications - vNet PoE

     Technical Specifications - vNet PoE

    Feature
    vNet PoE Interface (CDL-VNET-P)
    Logger Compatibility v6.00 hardware and higher (Includes Models: VL & SP 2000, 1000, 1200, 1016, 1416, 1400,4000)

    Ethernet Connectivity IEEE 802.3af, 10Base-T
    Connectivity cable Category 5/5e; RJ-45 connector; 1.83m (6 ft.) cable included

    Connectivity Cable Category 5/5e; RJ-45 connector; 1.83m (6 ft.) cable included

    LED Indicators link, activity, power, logger communications

    Device Configuration viewLinc Aware Service Plug & Play configuration (with viewLinc v4.3), PC-based configuration wizard, HTTP Web Interface

    Addressing DHCP/RARP, ARP-Ping, Static IP for IP address assignment, NetBIOS name

    Firmware Field upgradable firmware

    Power Consumption 625mW typical, 700mW max

    Power Supply
    (Included but not required when using PoE)

    North America: 12VDC/0.5 A max out, 120VAC in
    International: 12VDC/1.66A max out, 100-240VAC in
    Power Input
    (Optional, for use without PoE)

    12-30VDC, plugs into vNet jack labeled 12V
    Regulatory

    FCC Class A, CE EN 55011, Group 1, Class A; EN 61000-4-2 to -6; RoHS; WEEE

    Heating Effect on Measurements Temperature rise from electronics (important only for loggers with internal sensors): less than 0.05°C as seen by the logger sensor.

    Environmental Operating -25 to 70°C (-13 to 158°F), 0 to 90% RH non-condensing and not to exceed a mixing ratio of 38.5g/Kg
    Storage: -40 to 85°C (-40 to 185°F)

    Dimensions/Weight 10.2cm (4.0"); Width: 10.2cm (4.0"); Height: 4.3cm (1.7")  Weight: 180g (6.3 oz)
    Technical Specifications - Digi Wi-SP

     Technical Specifications - Digi Wi-SP

    Features
    Digi Connect Wi-SP
    Logger Compatibility v6.00 hardware and higher (Includes Models: VL & SP 2000, 1000, 1200, 1016, 1416, 1400,4000)

    Connectivity 802.11b wireless LAN interface
    Infrastructure (BSS) and Ad-Hoc Mode (IBSS)


    LED Indicators link, activity, power
    Device Configuration
    HTTP Web Interface, PC-based configuration wizard

    Addressing DHCP/RARP, ARP-Ping, Static IP for IP address assignment, NetBIOS name

    Firmware Field upgradable firmware

    Power
    Consumption

    4050mW
    Power Supply
    Flexible 9-30VDC power supply

    Power Input 
    9-30VDC @ 450 mA
    6-30VDC @ 1A max

    Regulatory
    • FCC Part 15, Subpart B
    • ICES-003
    • EN55022:1998, Class B
    • EN301 489-3:2002, Class B
    • FCC Part 15, Subpart C, Class B
    • Canada RSS 210 (Wireless)
    • AS/NZS CISPR 22:2002, Class B
    • VCCI V.3/2001.04, Class B
    • EN 300 328 V1.4.1 2003-04
    • EN55024
    • EN 301 489-3 V.1 4.1:2002
    • IEC/EN 60950-1 (2001)
    • UL/CUL 60950-1


    Environmental Operating
    Range
    Storage temperature: -40º C to +90º C (-40º F to +194º F)
    Operating temperature: -20º C to +65º C (-4º F to +149º F)
    Relative humidity: 5% to 90% (non-condensing)
    Altitude: 12,000 feet (3658 meters)

    Dimensions Length: 4.188 in (10.64 cm)
    Width: 1.680 in (4.267 cm)
    Depth: 0.999 in (2.537cm)

    Software Features

     
    • Robust on-board TCP/IP stack with built-in web server
    • Universal IP address assignment
    • Static IP, DHCP, Auto-IP
    • Dynamic DNS support (DHCP Option 12)
    • Secure web user interface (HTTP/HTTPS) with context-sensitive online help
    • Intelligent SNMP device management
    • Patented RealPort COM/TTY port redirection for Microsoft Windows®, UNIX and Linux

    Wireless Security

     

    • WEP (Wired Equivalent Privacy)
    • 64/128-bit encryption (RC4)
    • WPA/WPA2/802.11i
    • 128-bit TKIP/CCMP encryption
    • 802.1X EAP authentication
    • Dynamic WEP, LEAP (WEP only), PEAP, EAP-TLS, EAP-TTLS
    • PEAP/MSCHAPv2, PEAP/TLS, PEAP/GTC, PEAP/OTP,PEAP/MD5, EAP-TTLS/EAP-MD5, EAP-TTLS/EAP-GTC, EAP-TTLS/EAP-OTP, EAP-TTLS/EAP-MSCHAPv2, EAP-TTLS/EAP-TLS, EAP-TTLS/MSCHAPv2, EAP-TTLS/MSCHAP, EAP-TTLS/PAP, EAP-TTLS/CHAP
    • Enterprise and Pre-Shared Key (PSK) mode

    Wireless Interface

     
    • Standard: IEEE 802.11b
    • Frequency: 2.4 GHz
    • Data rate: Up to 11 Mbps with automatic fallback
    • Transmit power: 16 dBm typical
    • Receive sensitivity: -82 dBm @ 11 Mbps
    • Antenna connector: 1 x RP-SMA
    Technical Specifications - Digi ConnectPort GSW

     Technical Specifications - Digi ConnectPort GSW

    Feature
     
    Digi ConnectPort GSW
    Logger
    Compatibility
      v6.00 hardware and higher (Includes Models: VL & SP 2000, 1000, 1200, 1016, 1416, 1400, 4000)

    LED Indicators
      link, activity, power, signal strength

    Device
    Configuration

      HTTP Web Interface, PC-based configuration wizard
    Addressing   DHCP/RARP, ARP-Ping, Static IP for IP address assignment NetBIOS name

    Firmware   Field upgradable firmware

    Power Consumption


      6000mW
    Power Supply   12VDC power supply for 0° C to 60° C with locking barrel connector (included); Extended temperature power supply available separately

    Power Input   
    6-30VDC @ 1A max

    Regulatory  
    FCC Part 15 Subpart B & C, Class B; RSS-210: Issue 5; EN55022, Class B; EN301 489-3 Class B; EN300 328; EN61000-3-2 ,3; EN55024

    Environmental Operating/Storage Ranges

     
    • Temperature: -20º C to +60º C (-4º F to +140º F)
    • Relative humidity: 5% to 95% (non-condensing)
    Management   HTTP/HTTPS, CLI

     
     
    Protocols  
    UDP/TCP, PPP, Extended Telnet RFC 2217, Telnet, Reverse Telnet, Modbus to Modbus/TCP protocol conversion support
     
     
    Software  
    Device-initiated patented RealPort® with encryption COM port redirector

     
    Serial
    Ports
     
    RS-232/422/485 RJ-45 (software selectable); Up to 115 Kbps throughput; Signal support for TXD, RXD, RTS, CTS, DTR, DSR, DCD

    Ethernet
    Ports
     
    1 RJ-45 10/100Base-T, 10/100 Mbps (auto-sensing), Full or Half duplex (auto-sensing)

     
    Interfaces: Wireless (802.11b/g)
    Mode  
    Infrastructure, Ad-hoc
     
    Frequency  
    2.4 GHz
     
    Data Rate  
    Up to 54 Mbps with fallback
     
    Transmit Power  
    16 dBm typical (without antenna connected)
     
    Receiver Sensitivity  
    -73 dBm at 54 Mbps
     
    Antenna  
    2 dBi dipole antenna included, 1 x RP-SMA connector

     
    WLAN Security
     
    WEP   64/128-bit encryption (RC4); Open and shared mode
    WPA/WPA2/802.11i  

    128-bit TKIP/CCMP (AES) encryption
    Enterprise mode (802.1X): PEAP, TTLS, TLS, LEAP (WEP); GTC, MD5, OTP, PAP, CHAP, MSCHAP, MSCHAPv2, TTLS-MSCHAPv2
    Pre-shared key mode (PSK): 128-bit TKIP/CCMP (AES) encryption

    Surge Protection   4 kV burst (EFT) per EN61000-4-4, 2 kV surge per EN61000-4-5 (with included power supply)

    Ethernet Isolation   1500VAC min per IEEE802.3/ANSI X3.263

    Serial Port Protection (ESD)   +15 kV air 6 AP and +8 kV contact discharge per IEC 100-4-2

    Approvals
    Safety   UL60950; CAN/CSA C22.2 No. 60950; EN60950
    Emissions/Immunity





      FCC Part 15 Subpart B & C, Class B; RSS-210: Issue 5; EN55022, Class B; EN301 489-3 Class B; EN300 328; EN61000-3-2 ,3; EN55024