Visibility (MOR) measurement |
|
Measurement range (MOR) Accuracy |
5 ... 75 000 m with 1, 3 and 10-minute averaging +10 % range 5 ... 10 000 m ±20 % range 10 000 ... 75 000 m
|
Optical |
|
Scattering angle Optical monitoring
|
42° Window contamination measurement and compensation circuitry Optical path blockage detection Light source stability control
|
Operating environment |
|
Temperature Humidity Wind |
-40...+65 °C 0...100 %RH 60 m/s
|
Inputs and outputs |
|
Operating voltage Power consumption Outputs
|
100/115/230 VAC +/-10 %, 50-60 Hz 300 W maximum (60 VA + 240 VA defrosting heaters) Serial line RS-232 or opto-isolated RS-485 (2-wire) or optinal data modem Separate RS-232 maintenance line
|
Mechanics |
|
Dimensions Weight |
2.8 (h) x 0.9 (w) x 0.5 (d) m 37 kg, including interface unit, mast and base plate
|
For complete specifications, please see the brochure or user guide in "Documents".